Beijing Jia hua zhong xin Technology Co., Ltd

Products > Gas detector > Fixed gas detector > Prima XP gases detector
Product name : Prima XP gases detector
Item : 美国梅思安(MSA)
 Enlarge Image                   Back
←[Previous Product]              [Next Product]→


Details:
 Technical Parameters
 
Physical Characteristics
Housing material
Coated aluminum enclosure
Size
(220 x 162 x 100) mm
Weight
1.6 kg
Case Line
2 x M25 or 2 x 3/4 "NPT inlet line
 
Environmental Characteristics
Temperature
-40 ° C to +70 ° C
Humidity
15% to 90% RH non- condensing
Protection class
IP66
                               
Detection performance
Gas Category
Flammable , oxygen and toxic gases
Gas can be displayed
Combustible gas detector display reading for % LEL
Sensor types
Gas species range
Combustible 0-100% LEL
Oxygen 0-25% Vol.
Carbon monoxide (CO) 100, 200, 500, 1000 ppm
Hydrogen sulfide (H2S) 10, 20, 50, 100 ppm
Sulphur dioxide (SO2) 10, 20, 50, 100 ppm
Chlorine (Cl2) 5, 10 ppm
Ammonia (NH3) 50, 100, 500, 1000 ppm
Nitrogen dioxide (NO2) 10, 20, 100 ppm
Hydrogen cyanide (HCN) 10, 20, 30, 50 ppm
Hydrogen chloride (HCl) 10, 20, 30 ppm
Hydrogen fluoride (HF) 5, 10 ppm
Nitric oxide (NO) 100 ppm
Hydrogen (H2) 1000 ppm
Phosphine (PH3) 1 ppm
Silane (SiH4) 20, 50 ppm
Hydrogen bromide (HBr) 30 ppm
Germane (GeH4) 2 ppm
Fluorine gas (F2) 1 ppm
Diborane (B2H6) 1 ppm
Bromine (Br2) 10 ppm
Arsine (AsH4) 1 ppm
 
Transmitter job requirements
However reminder combustion gas sensors
Catalytic combustion sensor anti- poisoning .
Can withstand ultra- combustible gas range (0-100% LEL)
Operating Voltage
19.2到28.0 VDC, 24 VDC normally
The output signal
4-20mA output and optional HART, can load 300 ohms
Wiring
Standard 3 -wire or 4 -wire isolator output current type
Electrochemical sensors
Add the reaction medium without periodic sensor
Relays
Optional two relays - alarm and fault (1A/30VDC SPST)
Installation and accessories
Back
Backplane shell with easy installation to a wall or similar object
It pipeline installation
An optional mounting accessories pipeline
Sensor shield
Standard sensor shield to prevent outside interference environment
Duct mounting flange
Duct mounting flange to provide a catheter is used to detect gas
Sunshield
Provide sun shade for protection from direct sunlight high temperatures
 
The basic operating characteristics
Settings / Calibration
All instrument settings and calibration operations can be achieved through the built-in 4-button keypad or optional HART controller.
LED lights
Built- three status LED
Red LED - Alarm status
Yellow LED - Fault Status
Green LED - normal working state
Show
4.5 inches bright LCD screen , the scene shows the gas is monitored to detect the type and current readings .
 
Authenticate
Hazardous area certification
CE ATEX
Gas - II 2G Ex d ia (ia) IIC T4 Ga
Dust - II 2D Ex tb ia (ia) IIIC T130 ° C Db
-40 ° C ≤ Ta ≤ +70 ° C
 
UL Class I, Div 1, Group A, B, C, D
CMC, EX, CCCF
Safety Integrity Level
SIL 2
 
Manufacturers the ability to
Maintain
Provides maintenance and calibration of equipment
Field Service
Providing trained and authorized personnel on-site service
 
Aftermarket warranty
Sensor replacement
Users can purchase and replace the sensor itself
Warranty
Terms of reference MSA Chinese warranty

Related Products :
RAEGuard PID organic gas detector [FGM-100X]
美国华瑞(RAE)
RAEGuard PID organic gas detector [FGM-100X]
SP-1204A carbon monoxide gas detection alarm
美国华瑞(RAE)
SP-1204A carbon monoxide gas detection alarm
MX32 controller
法国奥德姆(OLDHAM)
MX32 controller
Odum OLCT200 fixed gas detector
法国奥德姆(OLDHAM)
Odum OLCT200 fixed gas detector
The OLCT20 gas / gas probe
法国奥德姆(OLDHAM)
The OLCT20 gas / gas probe
PrimaX IR Pro Infrared Gas Detectors
美国梅思安(MSA)
PrimaX IR Pro Infrared Gas Detectors
PrimaXP gas detectors
美国梅思安(MSA)
PrimaXP gas detectors
MSA Ultima XE fixed gas detectors
美国梅思安(MSA)
MSA Ultima XE fixed gas detectors

online service

点击这里给我发消息 点击这里给我发消息