Details:
 Introduction
 
HANNA unique Cal Check calibration diagnostic system is determined during the calibration electrode and the buffer performance. Such as measuring out of calibration system, a new calibration delay or calibrant error will beep tone to the user. Each instrument can be set unique ID identifier. In any mode, the user can use the HELP key to enter the on-screen help. Unique anti-interference design, can effectively prevent the interference caused by electromagnetic signals and instability. Instrument equipped with a USB interface, users can easily connect all kinds of different configurations of the computer, buy HI93200 WINDOWS software and the corresponding data line data transmission can be carried out on the data for further analysis and management
Precision laboratory analysis analyzer, automatic data storage, automatic locking end mode and user-defined setting function. And with automatic (ATC) or manual (MTC) temperature compensation; the ISE mode, the user can choose a variety of incremental method; pH calibration for seven built-in calibration point or 5-point calibration automatically recognizes two user- defined calibration points; conductivity measurements meet USP <645> USP specifications.
 
Product Features
The new design, with the screen calibration steps tips, excellent value for money
Complex USP USP <645> Conductivity Analyzer Standard three-step
5:00 pH automatic calibration, built-in 7 standard point, two custom point
HELP data lock key, lock measurement data can be easily recorded
Unique ion concentration incremental measuring method, a variety of optional ion concentration units
USB data interface, 400 sets of data storage, data management Excellence
PH-ORP-ISE-EC-TDS-NaCl-℃ 7 项 important indicator of water quality
 
HI3512 (HI3512C) microcomputer pH-ORP-ISE-EC-TDS-NaCI-° C measuring instrument
Range
pH
-2.0 To 20.0 pH
-2.00 To 20.00 pH
-2.000 To 20.000 pH
ORP
± 2000 mV
ISE
1.00 × 10-7 to 9.99 × 1010 (multiple units optional)
EC
0.000-9.999 μS / cm; 10.00-99.99 μS / cm; 100.0-999.9 μS / cm; 1.000-9.999 mS / cm; 10.00-99.99 mS / cm; 100.0-999.9 mS / cm; 0.01-400.0 mS / cm 1000 mS / cm
Resistivity
1.00-9.99 Ω • cm; 100-999 Ω • cm; 1.00-9.99 kΩ • cm; 10.0-99.9 kΩ • cm; 100-999 kΩ • cm; 1.00-9.99 MΩ • cm; 10.0-100.0 MΩ • cm seven measurement range
TDS
0.000-9.999 ppm; 10.00-99.99 ppm; 100.0-999.9 ppm; 1.000-9.999 ppt; 10.00-99.99 ppt; 100.0-400.0 ppt six measuring range
Salinity
Percentage Salinity: 0.0-400.0%
Temperature
-20.0 To 120.0 ℃
Resolution
pH
0.1pH (-2.0 to 20.0)
0.01 pH (-2.00 to 20.00)
0.001 pH (-2.000 to 20.000)
ORP
0.1 mV
1 mV
ISE
0.01/0.1/1
EC
0.001 μS / cm; 0.01 μS / cm; 0.1 μS / cm; 0.001 mS / cm; 0.01 mS / cm; 0.1 mS / cm
Resistivity
0.1Ω • cm; 1kΩ • cm; 0.01 kΩ • cm; 0.1 kΩ • cm; 1 kΩ • cm; 0.01 MΩ • cm; 0.1 MΩ • cm
TDS
0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
Temperature
0.1 ℃
Accuracy
pH
± 0.01pH (-2.0 to 20.0)
± 0.002pH (-2.000 to 20.000)
ORP
± 0.2 mV
ISE
± 0.5%
EC
Of reading ± 1% ± 0.01μS/cm
Resistivity
Of reading ± 1% (± 10Ω • cm)
TDS
± 1% of reading or ± 0.01 ppm
Temperature
0.2 ℃
pH calibration
Up to 5:00 automatic calibration, memory 8 calibration point (pH 1.68,3.00,4.01,6.86,7.01,9.18,10.01,12.45) and five user-definable calibration points
Ion Calibration
Up to 5-point automatic calibration, memory, five calibration points + 5 user-defined calibration points
Offset relative potential
± 2000 mV
Temperature Compensation
Automatic or manual temperature compensation, -20.0 to 120.0 ℃ (-4.0 to 248.0 ° F)
Electrode Type
PH electrode interfaces using BNC, HI7662 temperature probe
Data storage
Automatic or manual storage, 10 groups, each 5000 data
Data interface
USB interface, connected to the computer (with optional software and data cable data)
Power Supply
12 Vdc power adapter
Screen
240 × 320 dot-matrix color display with on-screen help, user confirmation and other functions
Use of the environment
0 to 50 ℃ (32 to 122 ° F); RH max 95%
Dimensions / Weight
235 × 207 × 110 mm/1800 g
Standard configuration
HI3512
Host, HI1131B acidity can be filled glass composite electrode, HI7071S electrode filling solution, HI76310 built-in temperature sensor tetracyclic EC / TDS electrode, HI7662 stainless steel temperature probe, pH standard buffer randomly bagged, HI76404N electrode special bracket, instruction manual in English
HI3512B / C
Host, HI1131B / C glass composite pH electrode, HI76310 built-in temperature sensor tetracyclic EC / TDS electrode, HI7662 stainless steel temperature probe, pH standard buffer randomly bagged, HI76404N special electrode holder, user manual in English
Optional Accessories
HI1053
Conical head can be filled glass composite pH electrode
HI1083
Round glass composite pH electrode Superfine
HI1131
Acidity can be filled glass composite electrode
HI1143
Acidity can be filled glass composite electrode
HI1230
Plastic composite electrode acidity
HI3230
Plastic composite redox electrode
HI7662
Stainless steel temperature probe
HI54710
Acidity calibration laboratory grade group
HI5004
Laboratory test certificate standard buffer acidity
HI5007
Laboratory test certificate standard buffer acidity
HI5010
Laboratory test certificate standard buffer acidity
HI7020
Redox standard buffer
HI7021
Redox standard buffer
HI7022
Redox standard buffer
HI7091
Redox standard buffer
HI7092
Redox standard buffer
HI7071
Conventional electrode filling solution
HI7061
Conventional electrode cleaning solution
HI70300
Electrode storage solution
HI920010
5-9 pin RS232 data transmission lines
HI92000
Data processing management software
HI920014
Data transmission lines

Related Products :
YSI 3100/3200 type laboratory Conductivity Analyzer
美国维赛(YSI)
YSI 3100/3200 type laboratory Conductivity Analyzer
COND 6 + portable conductivity meter
美国优特(EUTECH)
COND 6 + portable conductivity meter
MP522 Precision pH / Conductivity Meter
上海三信
MP522 Precision pH / Conductivity Meter
LA-EC20 laboratory conductivity meter
美国哈希(HACH)
LA-EC20 laboratory conductivity meter
YSI 5000/5100 Laboratory DO / BOD measuring instrument
美国YSI
YSI 5000/5100 Laboratory DO / BOD measuring instrument
CON6000 Conductivity Meter Bench
美国优特(EUTECH)
CON6000 Conductivity Meter Bench
MP515-01 Precision Conductivity Meter
上海三信
MP515-01 Precision Conductivity Meter
HI98331 Pen conductivity (EC) / Temperature (℃) analyzer
意大利哈纳
HI98331 Pen conductivity (EC) / Temperature (℃) analyzer

online service

点击这里给我发消息 点击这里给我发消息